Notifications
You must be signed in to change notification settings - Fork 61
Feature Request: Diagnostic System #1056
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
Show all changes
17 commits
Select commit
Hold shift + click to select a range
d98ff98
diagnostics: create initial draft feature request
timkl7 2bfdf70
diagnostics: draft feature request review ready
timkl7 c15eb92
Merge branch 'eclipse-score:main' into timkl7/fr-diag
timkl7 1100114
diagnostics: draft feature request review ready
timkl7 e7b4ba6
feedback from architecture community
timkl7 ee76197
Update docs/features/diagnostics/index.rst
timkl7 f74a0a0
Apply suggestions from code review
timkl7 8014655
updates from feedback
timkl7 c3dcf0c
Merge branch 'eclipse-score:main' into timkl7/fr-diag
timkl7 a52d6d7
updated structure and addressed feedback
timkl7 abc80a6
added diagram distributed view
timkl7 4395de0
added requirements
timkl7 243e187
updated directory structure
timkl7 347ee35
f2f arch ws feedback
timkl7 7ada4a6
Update docs/features/diagnostics/index.rst
timkl7 821b15f
review feedback added
timkl7 f68a47d
fixed typo
timkl7 File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -23,3 +23,6 @@ styles/ | |
.venv | ||
__pycache__/ | ||
/.coverage | ||
|
||
# Mac | ||
.DS_Store |
1,400 changes: 1,400 additions & 0 deletions
1,400
docs/features/diagnostics/_assets/score-diagnostics-distributed.drawio.svg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
1,219 changes: 1,219 additions & 0 deletions
1,219
docs/features/diagnostics/_assets/score-diagnostics.drawio.svg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,327 @@ | ||
.. | ||
# ******************************************************************************* | ||
# Copyright (c) 2025 Contributors to the Eclipse Foundation | ||
# | ||
# See the NOTICE file(s) distributed with this work for additional | ||
# information regarding copyright ownership. | ||
# | ||
# This program and the accompanying materials are made available under the | ||
# terms of the Apache License Version 2.0 which is available at | ||
# https://www.apache.org/licenses/LICENSE-2.0 | ||
# | ||
# SPDX-License-Identifier: Apache-2.0 | ||
# ******************************************************************************* | ||
|
||
.. _diagnostics_feature: | ||
|
||
Diagnostic and Fault Management | ||
############################### | ||
|
||
.. document:: Diagnostics | ||
:id: doc__diagnostics | ||
:status: draft | ||
:safety: QM | ||
:tags: feature_request | ||
|
||
|
||
.. toctree:: | ||
:maxdepth: 1 | ||
:glob: | ||
:titlesonly: | ||
:hidden: | ||
|
||
requirements/index | ||
|
||
Feature flag | ||
============ | ||
|
||
To activate this feature, use the following feature flag: | ||
|
||
``experimental_diagnostics`` | ||
|
||
|
||
Abstract | ||
======== | ||
|
||
We propose adding support for Vehicle Diagnostics via Service-Oriented Vehicle Diagnostics (SOVD) within S-CORE. | ||
SOVD offers a service-oriented, self-descriptive interface based on standardized RESTful APIs, | ||
eliminating the need for manually modeling diagnostic interfaces as required in UDS. | ||
This significantly reduces integration overhead and simplifies the onboarding of new ECUs. | ||
Additionally, SOVD enables scalable, secure, and cloud-ready diagnostics with real-time fault access and | ||
advanced data handling across platforms. Integrating SOVD into S-CORE will enhance developer efficiency, | ||
improve system maintainability, and support future-proof diagnostic workflows. | ||
|
||
The intent of this feature request is to define a high-level architecture for the diagnostic system. | ||
The components listed throughout this document require detailed feature requests in the future respectively. | ||
|
||
|
||
Motivation | ||
========== | ||
|
||
Currently there is no solution for vehicle diagnostics in S-CORE. | ||
Diagnostic is a core capability of automotive platform stacks and is required for various use-cases | ||
such as field troubleshooting, quality assurance, after sales, production, development and more. | ||
|
||
|
||
Rationale | ||
========= | ||
|
||
SOVD was chosen as the foundation for the diagnostic architecture because it offers a modern, | ||
service-oriented approach that aligns with the industry's shift toward Ethernet-based communication and scalable software-defined vehicle platforms. | ||
It provides a standardized and extensible interface that enables better interoperability across ECUs, testers, and external tools. | ||
|
||
|
||
Specification | ||
============= | ||
|
||
|
||
Architecture | ||
------------ | ||
|
||
The proposed concept consists of three main parts: | ||
|
||
1. A framework agnostic library to aggregate faults and integrate the diagnostic system into S-CORE | ||
2. A SOVD based diagnostic system | ||
3. Components to interface the diagnostic system with the outside – e.g. Tester or UDS based ECUs | ||
|
||
The diagram below shows the concept with the three subgroups connected. | ||
|
||
.. image:: _assets/score-diagnostics.drawio.svg | ||
:alt: Diagnostic stack component architecture | ||
|
||
|
||
The next diagram shows the concept in a distributed view to highlight components that are unique per system or per device. | ||
|
||
.. image:: _assets/score-diagnostics-distributed.drawio.svg | ||
:alt: Diagnostic stack component architecture | ||
|
||
In scope components | ||
------------------- | ||
|
||
The following components are considered in scope of this feature request. | ||
|
||
Fault Library | ||
|
||
- Provides a framework agnostic interface for apps or FEO activities to report faults - called "Fault API" in the S-CORE architecture. | ||
- Relays faults via IPC to central Diagnostic Fault Manager. | ||
- Enables domain-specific error logic (e.g. debouncing) by exposing a configuration interface | ||
- Reporting of faults additionally results in a log entry. | ||
- The interface needs to be specified further but will likely include: Fault ID (FID), time, ENUM fault type (like DLT ENUMs), optional meta data. | ||
- Fault lib is the base for activity specific, custom fault handling. | ||
- Can and should also be used by platform components to report faults. | ||
- Potentially source of faults to be acted upon - e.g. by Health and Lifecycle Management. | ||
- Also needs to enforce regulatory requirements for certain faults - e.g. emission relevant. | ||
- Decentral component. | ||
|
||
Diagnostic Fault Manager | ||
|
||
- Aggregates and manages diagnostic fault data from Fault libs across the system. | ||
- Provides centralized fault status to the SOVD Server. | ||
- Not part of SOVD specification directly but a stack specific diagnostic implementation. | ||
- Interfaces with the Diagnostic DB (persistency) to store and retrieve data. | ||
- Stores (persistently) central configuration (e.g. for debouncing thresholds) which can be loaded during startup by Fault libs. | ||
- Implements the operation cycle concept (suppressing faults during phases where faults are to be expected). | ||
- Central component. | ||
|
||
Diagnostic DB | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
- Potentially part of the Diagnostic Fault Manager process. | ||
- Stores static and runtime diagnostic data. | ||
- Is considered in scope due to the domain specific data format but internally uses S-CORE::Persistency. | ||
- The data format needs to be specified further but will likely include: | ||
- Diagnostic Trouble Code (DTC): OEM specific code, relevant for end-user. | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
- Fault ID (FID): ECU specific ID to uniquely identify every fault. | ||
- Count: occurrence count of DTC/fault. | ||
- Meta data: meta data related to fault occurrence. | ||
- Central component. | ||
|
||
SOVD Server | ||
|
||
- Central entry point for all diagnostic requests via SOVD. | ||
- Implements the SOVD API and dispatches requests to services, DB, and fault manager. | ||
- Manages authentication, configuration, and data access via IPC. | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
- SOVD communication via HTTP. | ||
- Central component. | ||
|
||
Service App | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
- Is a base concept to extend the system with system-specific diagnostic services/routines (e.g. DTC clear, ECU reset, Flash Master). | ||
- Interfaces with the SOVD Server via IPC. | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
- Base for all specific service app implementations. | ||
- Central component derived from base service app. | ||
|
||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
SOVD Gateway | ||
|
||
- Forwards SOVD requests to appropriate backend targets (e.g. adapters, proxies, clients). | ||
- Acts as a router between clients and distributed SOVD components. | ||
- Supports multi-ECU SOVD communication. | ||
- Central component and unique per system. | ||
|
||
SOVD Client | ||
|
||
- Off-board, on-board or cloud client that initiates diagnostics via SOVD protocol. | ||
- Can be used by developers, testers, ECUs or cloud services; should be deployment agnostic. | ||
- Handles access control on the client side – e.g. by providing relevant certificates. | ||
- Central component - but could be deployed mutliple times (e.g. one on-baord and one off-baord). | ||
|
||
Classic Diagnostic Adapter | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
- Translates SOVD service calls to UDS commands. | ||
- Enables backward compatibility with legacy ECUs that only support UDS. | ||
- Configured via ODX files describing ECU-specific UDS expectations. | ||
- UDS transport layer (e.g. DoIP or other vendor specific transports) shared with UDS2SOVD Proxy. | ||
- Central component and unique per system. | ||
|
||
UDS2SOVD Proxy | ||
|
||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
- Allows for the mapping of any UDS service to SOVD functionality in an arbitrary way for backward-compatible testers. | ||
- Acts as a local translation layer between UDS clients and SOVD stack. | ||
- Configured via ODX files to define what is exposed. | ||
- Implements the UDS session handling concept. | ||
- UDS transport layer (e.g. DoIP or other vendor specific transports) shared with Classic Diagnostic Adapter. | ||
- Central component and unique per ECU (one per ECU or per System is possible). | ||
|
||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
Out of scope components | ||
----------------------- | ||
|
||
The following components are out of scope for this feature request but are included for context. | ||
Each one is briefly described to illustrate its role within the overall system architecture and | ||
to highlight any resulting requirements or constraints imposed by the diagnostic system design. | ||
|
||
Logging | ||
|
||
- Enables the Fault Library to log fault events. | ||
- All SOVD components can interact with logging. | ||
|
||
Configuration Manager | ||
|
||
- Provides configuration data to the SOVD Server (e.g. ECU layout, variant, parameters). | ||
- Enables parametrization of applications. | ||
|
||
Authentication Manager | ||
|
||
- Manages authentication and authorization for incoming SOVD requests. | ||
- Ensures only valid users or clients can access services. | ||
|
||
Crypto | ||
|
||
- Provides cryptographic services – e.g. securely store and retrieve diagnostic certificates. | ||
- Used by Authentication Manager. | ||
|
||
Persistency | ||
|
||
- Provides persistent data storage. | ||
|
||
Flash Service App | ||
|
||
- Specialized extension of the Service App to handle ECU flashing. | ||
- Provides routines for software update/bootloader access via diagnostics. | ||
|
||
Rest of Vehicle UDS | ||
|
||
- Represents legacy ECUs in the vehicle that only speak UDS. | ||
- Interact via the Classic Diagnostic Adapter (SOVD2UDS). | ||
|
||
Rest of Vehicle SOVD | ||
|
||
- Other ECUs in the vehicle that already support SOVD natively. | ||
- Can communicate directly with the SOVD Gateway. | ||
|
||
UDS Tester | ||
|
||
- Traditional diagnostics tester that uses UDS protocol. | ||
- Communicates with the UDS2SOVD Proxy for limited diagnostics access. | ||
|
||
|
||
Requirements | ||
------------ | ||
|
||
The related requirements can be found in :doc:`requirements/index`. | ||
|
||
|
||
Backwards Compatibility | ||
======================= | ||
|
||
UDS2SOVD Proxy and Classic Diagnostic Adapter (SOVD2UDS) ensure compatibility with legacy UDS systems. | ||
ODX as a standardized exchange format further ensures compatibility with proprietary diagnostic data models. | ||
|
||
|
||
Security Impact | ||
=============== | ||
|
||
The introduction of a SOVD based diagnostic stack has significant security implications due to its capabilities and network-based communication model. | ||
Diagnostics inherently allow access to system information, state manipulation, coding, and software updates - all of which pose risks if accessed by unauthorized actors. | ||
SOVD, based on REST, includes modern security features such as HTTPS and token-based authentication, | ||
but also introduces a broader attack surface compared to traditional UDS, which relies on more isolated, session-based access. | ||
If improperly secured, diagnostic interfaces could be exploited to trigger unauthorized routines or inject malicious software. | ||
This may enable new threat scenarios and attack paths, particularly over external or less trusted networks. | ||
To mitigate these risks, the diagnostic stack shall enforce secure communication via HTTPS, | ||
authenticate endpoints using certificates (see architecture diagram), and implement strict access control mechanisms. | ||
While diagnostics do not directly impact functional safety, a successful attack could indirectly influence safety-relevant functions | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
- for example by setting the system into a different state. | ||
Therefore, the overall security architecture must be revisited in detail to assess and mitigate potential risks introduced by the SOVD integration. | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
Since diagnostics is QM, even being able to breach into the SOVD stack must not violate safety guarantees. | ||
This implies that session/mode-sensitive operations must be treated by the implementing apps in a way that doesn't impact safety. | ||
The client lib(s) need to be developed with the same quality standards as safe components to ensure that and also provide FFI guarantees. | ||
|
||
Safety Impact | ||
============= | ||
|
||
At this point in time no direct safety impact is foreseen. The expected ASIL level is QM. | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
Configuration Management could have a safety impact but is handled in another feature request and out of scope of this document. | ||
As pointed out in "Security Impact", a breach in the diagnostic system could theoretically effect safety-relevant functions | ||
- for example by setting the system into a different state. | ||
The Fault Library could also have a safety impact if faults are propagated and act upon by other components | ||
- for example Health and Lifecycle Management. | ||
|
||
|
||
License Impact | ||
============== | ||
|
||
There are no license restrictions preventing the implementation of an open-source SOVD stack at this time. | ||
While SOVD is currently in the ISO standardization process (ISO/DIS 17978) [#s1]_, the relevant parts - especially Part 3, | ||
which defines the API - are already publicly available for purchase as Draft International Standards (DIS). | ||
These drafts are considered stable and are typically subject only to minor editorial changes before final publication. | ||
As such, referencing the current DIS versions is sufficient for implementation purposes, and does not pose any legal or license-related risk. | ||
timkl7 marked this conversation as resolved.
Show resolved
Hide resolved
|
||
Once the final ISO standard is published, the delta to the current drafts is expected to be minimal and can be easily addressed. | ||
|
||
The license impact regarding publication of XML schemata to handle/convert ODX files as per ISO 22901 needs to be evaluated. | ||
|
||
|
||
How to Teach This | ||
================= | ||
|
||
A good starting point to get an overview of SOVD is the overview pages provided by ISO [#s1]_ and ASAM [#s2]_. | ||
|
||
|
||
Rejected Ideas | ||
============== | ||
|
||
An UDS first based diagnostic system was considered but rejected. | ||
The current market trend clearly indicates the move towards SOVD. | ||
Additionally, there a multiple well established proprietary UDS stacks and tools available. | ||
Because no FOSS SOVD stack exists currently, it presents an opportunity for S-CORE to provide value and increase adoption. | ||
|
||
|
||
Open Issues | ||
=========== | ||
|
||
- Interfacing concept with Autosar Adaptive Diagnostic Stack for mixed stacks and/or a transitional phase | ||
- Evaluate publication of XML schemata to handle/convert ODX files as per ISO 22901 | ||
- Provide sequence diagram for a use case | ||
- Is the fault lib the source for faults to be acted upon by Health and Lifecycle Management? | ||
- List regulatory requirements for certain faults/DTCs - e.g. emission relevant faults | ||
- Provide recommended transition/migration scenario for UDS based components moving to SOVD | ||
- Decide if SOVD communication inside the ECU uses IP based communication or an alternative such as UDS (Unix Domain Sockets) | ||
- Decide on a common concept for Service Validation. How are Services Validated and where (Server vs. Service)? | ||
- For Service Validation: How do Services access the state of the ECU and the state of certain apps? | ||
- Add concept of how to interact with ECU State Management | ||
|
||
|
||
Footnotes | ||
========= | ||
|
||
.. [#s1] "SOVD Standard ISO/DIS 17978", ISO, https://www.iso.org/standard/85133.html. | ||
.. [#s2] "ASAM SOVD Overview", ASAM, https://www.asam.net/standards/detail/sovd. |
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.