Abstract
This study explores the potential and feasibility of Electrical Capacitance Tomography (ECT) for monitoring mass flow rates (MFR) of chopped maize in precision agriculture. The research, conducted using a stationary forage harvester stand, involved the analysis of whole Inagua maize samples weighing 5, 10, and 15 kg. These samples were further divided based on two moisture contents of 57% or 68%, and the geometric mean particle value was 9.39–12.69 mm, depending on the number of knives in the cutting unit. A 12-electrode capacitive sensor measured MFR, demonstrating less variation during calibration than a 6-electrode sensor. The study revealed a significant relationship between moisture content, particle size, and sensor capacitance, which was crucial for accurately converting capacitance measurements to MFR. The maximum mean value of the MFR was 3.18 kg·s–1 ±0.93 kg·s–1, compared to the theoretical 3.75 kg·s–1. These findings have practical implications, highlighting the potential of ECT for precision agriculture applications. The study’s results could significantly impact the development of precision farming technologies, particularly forage harvester monitoring systems. By providing a more accurate and reliable method for measuring mass flow rates, the ECT system could enhance the efficiency and quality of crop production. The study also underscores the need for further research, particularly in technology improvement, to improve measurement accuracy and adapt the ECT system to the dynamic field conditions of precision farming.
Similar content being viewed by others
Introduction
Advanced precision farming technologies use specialised machines equipped with sensors for monitoring and actuators and are supported by a computer system, which affects the change of rules in crop management1. Software-supporting hardware systems enable accurate recording of data matrices that reflect the variability of crop yields and soil properties in spatial distribution2. Using a set of current and historical data allows for the adjustment of the plant type, as well as precise fertilization and plant protection, taking into account the specific characteristics of individual soil conditions, plants, and their condition3. Precise agronomic technologies and the dosing of the right fertilizer ingredients for optimal crop protection are essential for achieving higher yields and better quality of cereals and maize4. The research results and conclusions contribute to creating a more comprehensive offer of new precision farming technologies by machine manufacturers, which depends on the accuracy of measuring systems, the precision of the sensors, their integration into work teams, and the quantity and quality of information they provide5.
One of the links in precision farming is the monitoring and mapping of yields, which takes place during the harvest of plants. Combine harvester manufacturers have offered a range of measurement kits such as the HarvestLab or the Crop Sensor. Sensor instrumentation equipment plays a crucial role in the real-time monitoring of yields and grain quality and provides farmers with valuable analytical information to optimise production techniques6.
The extensive experience and results from cereal harvesting have laid the foundation for developing yield monitoring systems for other crops, especially green plants. Initial tests conducted between 2000 and 2005 at the Warsaw University of Life Sciences (WULS) using a trailed forage harvester highlighted the necessity for refining methods to measure the MFR of material transported by the machine’s working units7. The first research in this domain was initiated in the early 1990s8. MFR monitoring tests, carried out to varying extents, involved measurements such as torque on the grinding drum and the chop projector8, the gap between smooth and crushing rollers positioned just ahead of the chopping unit9, the volume of the material stream in the discharge spout, the force exerted by the chaff stream on the strain gauge10, and the mass of the chaff on the trailer11. Verification of the listed methods, also in interlaboratory studies, indicated varying measurement accuracy, depending on the technical advancement of the sensors used and the uniformity of the plant material distribution within the machine’s working units12. Ensuring consistent thickness of compacted plants along the rollers’ length, uniform density of the chaff MFR within the discharge spout curve, and equal load on the measurement sensors was crucial.
Although yield monitoring technologies are readily available for crops like corn, soybeans, and cereals, they are less common for horticultural crops such as berries, field vegetables, and orchards. This gap is highlighted in the review article, discussing different approaches to measurement – near and far, direct and indirect13. The potential of using capacitive measurement methods, giving examples from the research results for sugar beet and potatoes14, chopped corn15, and hops16. However, further research is needed to understand and fully optimise this method for horticultural crops. The evaluations show that the shape of corn particles, moisture content, and temperature stability of the sensor are the three variable parameters affecting the accuracy of the developed system17.
With the development of measurement techniques in other technical and scientific fields, research has been undertaken to develop more advanced crop monitoring systems, especially for those crops for which current systems operate with unacceptable accuracy. This applies particularly to green plants harvested at variable spatial maturity, associated with material moisture content above 50%, e.g. maize. The primary criteria for evaluating these systems should be simplicity and reliability in field conditions. One such system is ECT. With its simplicity and cost-effectiveness, ECT proves to be well-suited for real-world applications as a non-intrusive method for monitoring plant material yield. The measuring elements must be positioned around the measuring area in a manner that does not disrupt the flow of plant material. ECT meets this requirement because it does not contain any moving mechanical components, which directly affects the increased durability and lifespan of the measuring device, especially in dynamic conditions in agricultural fields, providing certainty of its long-term use and operational reliability. ECT is employed for monitoring two-phase flows or in pneumatic transport, such as conveying bulk materials with uniform structures18. Recent advances in ECT technology have demonstrated its potential to overcome some traditional challenges faced in agricultural settings, such as non-uniformity in sensor readings due to variable crop densities and moisture levels19. Recently, the permissible accuracy of measurements using ECT has been confirmed, the method has been validated, and the reliability of the obtained data has been verified20. Its use in agricultural engineering was indicated. Such studies convince potential users of the wide range of possibilities for using this technology in precision farming21. This method has been utilised to monitor combustion processes in industrial burners and aircraft engine chambers. The flame position and structure were visualised, and spatial resolution and signal level change for different flow conditions were determined22. Considering the use of top-class sensors and increasing the precision of measurements, ECT has a vast potential range of applications23.
This identified knowledge gap was the impetus for adapting ECT within a forage harvester to measure the MFR of chopped maize plants intended for silage. The structure of the chopped material from whole maize plants and its higher moisture content than cereal grains present more significant challenges for researchers. Specifically within this research domain, studies on the measurement of cut corn throughput15 utilised a parallel plate capacitive sensor. Laboratory experiments have shown that the density of the cut corn material and its moisture content affect the accuracy of the measurement.
Although agriculture enjoys advanced technologies and computer support, new challenges in integrating crop monitoring methods are constantly emerging. Modern techniques such as machine vision and sensor fusion offer great opportunities for real-time monitoring of crop conditions. The development of digital technologies in agriculture creates a need for reliable and widely applicable crop monitoring systems, which is important for the sector’s future13.
The study focuses on applying ECT in agricultural engineering and sensor technology, presenting innovative solutions to identified problems in this field. The study aimed to evaluate the accuracy of MFR measurements of chopped maize plants with different particle sizes and moisture levels. The studies were conducted under controlled stationary conditions using a trailed forage harvester model. The test stand and the harvester were equipped with appropriate equipment to validate the ECT method. Adaptation of ECT to forage harvesters opens new possibilities for more accurate crop yield measurements, avoiding physical interference and typical wear problems associated with conventional sensors.
The research problem was formulated as a question. How can ECT be effectively adapted to measure the MFR of chopped maize plants in a forage harvester, overcoming challenges associated with the material’s high moisture content and variable density to improve real-time yield monitoring in precision agriculture?
Based on the context provided, here are two scientific hypotheses. These hypotheses were tested through a series of experiments and data analysis, which are detailed in the following sections.
Hypothesis 1
ECT technology, when adapted for use in a forage harvester, provides accurate measurements of MFR of chopped maize, regardless of variations in particle size and moisture content.
Hypothesis 2
Using an ECT sensor equipped with 12 electrodes in the chopper discharge chute enables reliable correlation of capacity changes with the actual mass flow of chopped corn, which confirms the effectiveness of this method in precise monitoring of green crop yields.
The key innovation in this study is using a 12-electrode ECT sensor, which is a significant improvement over initial attempts that used 6-electrode sensors. The introduction of 12 electrodes allowed for much better mapping and analysis of capacitance changes, resulting in more precise and reliable results. This study opens up new possibilities for ECT applications in precision agriculture, particularly in monitoring the yield of green crops. It offers the potential to improve measurement accuracy.
Materials and methods
Plant material
The research material, unique in composition, comprised whole maize plants of the Inagua variety, a medium-late variety (FAO number 230–240) cultivated explicitly for grain and silage. These maize plants were manually harvested using a brush cutter and transported to the WULS Institute of Mechanical Engineering via a volume trailer.
The moisture content of the plant material was meticulously determined using the dryer-weighing method24. Randomly taken samples of 25 g were weighed on an electronic scale (WPS 600/C, Radwag, Radom, Poland) with an accuracy of 0.01 g, dried in a laboratory dryer (SLW 115, Pol-Eko Aparatura, Wodzisław Śląski, Poland) at 105° by 24 h, and weighed again after drying. The moisture content of the material was calculated based on the mass of wet matter. The particle size distribution was analysed for each combination of technical parameters under which the forage harvester operated, including a single sample, material moisture, and several knives. The particle size distribution of the chopped maize plants was conducted following the guidelines outlined in ASABE Standard S424.1, utilising an oscillating sieve separator25. The resulting particle size distributions were then approximated using the Rosin-Rammler-Sperling-Bennett model26, and their characteristics were evaluated based on distribution measures27.
Measurement method
The concept of measurement in ECT revolves around analysing capacitance changes gathered from several to a dozen or so electrodes positioned around the research area (refer to Fig. 1). In this method, the capacitance changes values are significantly influenced by the distribution of dielectric constants of one medium within another, as per Eq. 128. This factor plays a crucial role in the accuracy of the ECT method.
where Cij—represents the capacitance between electrodes i and j, F, φi—denotes the potential at electrode i, V, φj—refers to the potential at electrode j, V, ε(x,y)—stands for the distribution of electric permittivity, F·m[–1, φ(x,y)—signifies the potential distribution, V, and (x,y)—the Cartesian coordinates, play a crucial role in understanding the Spatial distribution of the measurements, m.
The ECT system comprises three modules: sensors, a measurement system, and a computer (Fig. 2). The sensors consist of electrodes symmetrically positioned around the research area. Each pair of electrodes forms a distinct type of air capacitor. The measurement system is tasked with measuring the capacitance of each pair of electrodes. The computer with the free Python v. 3.11.5 software (https://www.python.org) serves crucial additional functions. Firstly, it oversees the operation of the measurement system, and secondly, it archives measurement data and analyses the results obtained.
A critical component of an ECT system is its sensing electronics, which measure the minute inter-electrode capacitances. While several circuit designs can measure such low capacitance values29, practical ECT applications demand that these circuits be immune to stray capacitance, straightforward, and responsive. The charge/discharge circuit meets these requirements and has been chosen for suitability. A vital benefit of this choice is the simplicity of the electronic components, allowing for straightforward integration, as demonstrated in Fig. 3.
However, practical implementation of ECT demands a measuring circuit immune to stray signals, simple design, and quick response. The charge/discharge circuit, fulfilling these criteria, was thus adopted. A significant advantage of this charge/discharge-based ECT system lies in its electronic simplicity and cost-effectiveness, facilitating straightforward integration30. The charge/discharge circuit is displayed in Fig. 4. Each complete cycle of operation consists of two phases: the charge phase and the discharge phase. During the charge phase, switches S2 and S4 are closed, and S1 and S3 are opened. The charge current flows from the voltage source Ve through the measured capacitance to operational amplifier A1 with resistance feedback Rf and capacitor Cf. Similarly, switches S1 and S3 are closed during the discharge phase, and switches S2 and S4 are opened. The charge stored in the measured capacitance discharges to the ground, and the right side draws current from operational amplifier A2. A differential amplifier A3 with a gain (depending on the combination of resistors R1 and R2) is used to sum these two signals, producing a DC measurement signal Vout proportional to the measured capacitance.
The cornerstone of the system is the measurement system, comprising a series of capacitive-voltage converters, a multiplexing system, and an analog-to-digital converter. Capacitance change signals obtained from individual pairs of electrodes are sequentially multiplexed and processed in an analog-to-digital converter. The resulting digital signals are then transmitted to the computer, where the Python software, leveraging data collected from all pairs of electrodes, presents changes in the research space on the monitor screen.
The capacitance responses between electrode pairs are significantly influenced by the geometric configuration of the sensor electrodes, in addition to the permittivity distribution. This results in notable differences in magnitude and distribution profiles. Normalisation of the measured capacitances and sensitivities is essential before analysis to mitigate these effects and reduce systematic errors in the measurement system.
This comprehensive relationship for all electrode pairs is briefly represented in matrix form, as shown in Eq. 231.
where: Cn is an m×1 matrix containing the normalised capacitances of the electrode pairs; m is the number of unique electrode pair combinations (e.g., 66 for a 12-electrode sensor); Kn is a k×1 matrix representing the normalised pixel permittivity; k is the number of pixels representing the sensor cross-section; Sn is an m×k matrix containing the normalised sensitivity matrices for each electrode pair.
Sensitivity distributions, also known as sensitivity maps, are crucial for image reconstruction and are typically derived from numerical solutions to the Laplace equation, as stated in Eq. 332.
where: φ is the potential distribution.
Finite Element Methods are often employed because it is challenging to find analytical solutions for Eq. 3. In our studies, we use Ansys 2020 R2 software, https://www.ansys.com, (MESco, Bytom, Poland) to differentiate potential distributions between two electrodes, calculating electric field distributions E1 and E2 for source and detector electrodes, respectively.
The sensitivity of electrode pair i–j at a spatial location (x, y) is determined by dot-multiplying the two electric fields, as illustrated in Eq. 433.
where: \(\:{\overrightarrow{E}}_{i}\) and \(\:{\overrightarrow{E}}_{j}\) represent the electric field distributions when electrodes i and j are the source electrodes, respectively, with an excitation voltage U applied, and Ω denotes the entire sensing region.
Each sensitivity matrix quantifies the response of an electrode pair to a stimulus within the sensor area, proportional to the change in inter-electrode capacitance caused by a pixel filled with high-permittivity material. In contrast, other pixels are filled with low-permittivity material. The presence of an object in different locations variably affects the same electrode’s capacitance, whereas the exact location can differentially influence various electrode capacitances.
As per our method, the sensitivity map for a specific electrode pair is normalised according to Eq. 533. Figure 5 illustrates typical sensitivity maps and their normalisations.
The ECT system operates using precisely standardised values of dielectric permittivity and inter-electrode capacitance, which are always within the range (0.1). Such precision results from a careful calibration process of each sensor, which expresses the attention to detail in our work and guarantees the high accuracy of measurements performed by the system.
The first step in the calibration process involves using a sensor filled with a low-dielectric permittivity material (Fig. 6). The key here is the selection of air as the reference material, which has a dielectric permittivity of 1. This step establishes the interelectrode capacitance CL values corresponding to the low dielectric permittivity value. The next step in calibration involves using a different reference material to determine capacitance values for higher dielectric permittivities. Equally important is the careful selection of this second material, which should ideally match the dielectricity of the object being tested, which allows the second set of interelectrode capacitance CH values to be obtained. The scaling factor WC concerning the transported polyethylene mass mtp had a linear relationship; WC = 0.1752mtp, with the determination coefficient R2 = 98.67%. Assuming linearity, an expression for the normalised capacitance value Cn can be Eq. 634.
where: Cn – represents the normalised capacitance, CM – denotes the capacitance of the plant material, F, CL – signifies the capacitance corresponding to low dielectric permittivity, F, CH – refers to the capacitance corresponding to high dielectric permittivity, F.
The sensor was calibrated using a material with a dielectric permittivity 2.6, corresponding to a normalised capacitance 1. If an object with a permittivity of 5.2 is placed, these values will double. In some measurements, the values exceeded 1. The calibration process is crucial as it directly affects the sensor’s performance, and any deviation from the expected values can impact the accuracy of the measurements.
An essential element of ECT technology is the appropriate selection of the number and size of electrodes. These two factors directly affect three critical aspects of the system: axial and radial resolution, measurement sensitivity, and data acquisition speed. Increasing the number of electrodes while maintaining the same device length, which reduces the size of individual electrodes and decreases measurement sensitivity, is a technical challenge. For each electrode configuration, it is necessary to maintain an appropriate balance between their number and size, as well as the resolution and sensitivity of the system. Another critical aspect is to ensure that the capacitance change values remain within acceptable noise levels of the measurement system.
It is reasonable to assume that axial resolution, and thus the length of the electrodes, will be of lesser importance, especially for processes that remain consistent along the sensor axis. The radial resolution is expected to improve with an increased number of electrodes. In existing ECT systems, sensor sets typically comprise 6, 8, or 12 electrodes. The measurement system’s sensitivity remains consistent for a smaller number of shorter and a more significant number of more extended electrodes, provided that the sensor dimensions remain constant. Tests conducted on a model stand using polyethylene granulation showed that the measurement accuracy increased with several electrodes. The variation of the WC scaling factor, which is a measure of the sensor’s ability to accurately measure the mass of the transported polyethylene granulate, for 12 was smaller than for 6 sensor electrodes, and the evidence was a higher value of the linear regression determination coefficient, 98.67%, and 96.79%, respectively. Therefore, a sensor with 12 electrodes was used in the tests.
Measuring sensor
As part of the adaptation of the ECT system, a measurement 12 electrode sensor was designed and manufactured, the diagram of which is depicted in Fig. 7.
The sensor design is centred around a steel sleeve (1) with an internal diameter of 183 mm and a wall thickness of 14.5 mm. The lower (2) and upper (3) steel collars were affixed to the sleeve using M8 screws (4), with holes drilled in these flanges to facilitate integration of the sensor with the forage harvester. Twelve electrodes (5) were fashioned from a steel pipe with an internal diameter of 169 mm and a thickness of 2 mm. The electrodes measured 120 mm in height and 36 mm in length, with each electrode having a 30 mm long M4 steel threaded rod (6) welded. Utilising spacer sleeves (7, 8), the electrodes were fastened to the chamber using an M4 nut. To establish connections between each electrode and the SMB connector (9), a specialised spacer sleeve (10) was crafted and secured to the chamber with four M3 screws (11). During the final construction phase, the void between the electrodes and the chamber was filled with resin (12) and subsequently shaped to achieve the desired diameter of 165 mm. The geometric model and perspective view of the 12-electrode sensor are presented in Fig. 8. In Fig. 8a, the view visually depicts the physical sensor, showing how the 12 electrodes are arranged in reality. It provides a schematic representation of the sensor’s key components. Figure 8b shows the structure of a 12-electrode sensor featuring visible electrodes and connectors for integration with the measurement system.
Measuring stand
The adaptation of the ECT system was conducted under stationary conditions at the Department of Biosystems Engineering, WULS, utilising a model of a trailed forage harvester (Z 374, SIPMA, Lublin, Poland) powered by the power take-off (PTO) of an agricultural tractor (1234 Ursus, Warsaw, Poland) with an output of 85 kW. With a rotational speed of 1000 rpm, the tractor’s PTO drove the cutting disc shaft and, from it, a hydraulic pump that supplied oil to two hydraulic motors. The upper hydraulic motor propelled the upper drawing-compaction rollers, while the lower motor powered the lower drawing-compaction rollers and the adapter. Knives with a straight cutting edge were set at 5.9° to the radial cutting direction. The knife blade length was 373 mm, the blade angle was 25°, the clearance angle was 25°, and the gap between the knife blade and the edge of the counter blade was 0.2 mm. The grinding unit featured a corrugated bottom plate and straight projector blades with a sharp leading edge, with the working gap between these components set at 8 mm at the inlet and 2 mm at the outlet25. The individual components of the measurement station are depicted schematically in Fig. 9, while the overall view of the station with the ECT sensor attached is presented in Fig. 10.
The forage harvester underwent appropriate modifications for the research and was outfitted with measuring instruments. Input samples of plant material were weighed using a decimal scale (WDO-150, Metalowiec, Średnica, Poland) with an accuracy of ± 0.2 kg. In contrast, the material was conveyed to the machine via a belt conveyor propelled by an electric motor through a V-belt transmission35. The chopped chaff was gathered in a canvas container, with the metal frame of the container attached to a CLP 500/LC510 electronic scale (Radwag, Radom, Poland), boasting a capacity of up to 500 kg and an accuracy of 0.1 kg. The research material comprised maize plants of the Inagua variety intended for silage, sourced from the fields of the Agricultural Experimental Station in Wilanów-Obory, affiliated with WULS.
View of the measurement station with a sample of corn plants evenly distributed on the transport conveyor and a 1234 Ursus tractor connected to the Z 374 forage harvester (a) and method of mounting the ECT sensor (b) on the discharge chute of the forage harvester, and a package of pressure and turbine oil flow sensors connected to the hydraulic system (c); own elaboration.
The course of the study
For varying weights of individual samples of maize plants (5, 10, 15 kg), different numbers of knives on the chopping unit of the forage harvester (5, 10), and varying moisture content of the maize material (68%, 57%), along with established technical parameters including the speed of the feeding belt conveyor at 1 m·s–1 for plant material and the angular speed of the PTO at 104.7 s–1 (rotational speed of 1000 rpm), the following physical quantities were measured: speed of the belt conveyor (measured by timing the 8 m distance travelled by the belt with a stopwatch); rotational speed and torque of the PTO (measured using an encoder with an accuracy of ± 6 rpm integrated with a torque sensor with an accuracy of ± 0.8 N·m, MTR 1000, Laboratory of Electronics, Poznań, Poland); rotational speed of the cutter disc shaft (measured using an incremental encoder with a roll 8.5802.1275.1000, with a resolution of 1000 rpm and accuracy of ± 6 rpm); pressure and absorbency of hydraulic motors driving the upper and lower feeding and compaction rollers, as well as hydraulic oil pressure at the exit from the hydraulic motors of the rollers (measured using piezo-resistive pressure sensors (PC-28) with a measuring range of 0–25 MPa ± 0.01 MPa, and turbine oil flow sensors (FT12) with a measuring range of 0–76 dm3·min–1 and an accuracy of ± 0.1 dm3·min–1 included in the set of FT12PM28KT42.TR sensors; APEK, Warsaw, Poland); rotational speed and torque of the shaft driving the lower drawing-compaction rollers (measured by an encoder with an accuracy of ± 5 rpm, integrated with an inductive torque gauge with an accuracy of ± 0.8 N·m, MT 500, Laboratory of Electronics, Poznań, Poland). An inductive sensor, CL-70-200, was employed to measure the thickness of the material layer between the rear compaction rollers, providing measurements with an accuracy of ± 1 mm. Additionally, a semiconductor thermometer was utilised to gauge the temperature of the hydraulic oil, measured from the combined output of the engines to the oil tank. Throughout the tests, the oil temperature was maintained at 30 ± 5 °C. Data were gathered at a sampling rate of 50 Hz on a personal computer overseeing the input/output (I/O) modules, utilising a high-speed Hottinger Baldwin DMCplus digital interface card and CATMAN v. 2.1 software, https://www.hbm.com (HBM, Darmstadt, Germany). These parameters were measured to assess the repeatability of technical settings in individual measurement tests.
For the most significant sample mass of maize plants, which was 15 kg, the theoretical material flow rate at the entrance to the forage harvester was 3.75 kg·s–1. This relatively low value was necessary to safeguard the forage harvester’s feed unit against blockages caused by the maize plants and to ensure smooth material movement, thus minimising measurement errors. Following each test, a 25 g sample of plant material was extracted to determine its moisture content. The dryer-weighing method was employed for moisture measurement23. The research encompassed recording signal changes using ECT for various precisely weighed samples of plant material, each with known moisture content and a specified number of knives in the chopping unit.
Preparation of research results and statistical analysis
The recorded data from the sensor set underwent processing using a third-order Butterworth high-pass filter36. Further details are provided in subsection 3.2. The test results were analysed using the Statistica v. 13.3 program, https://www.statsoft.pl (StatSoft Poland Ltd., Cracow, Poland). This involved determining linear regression equations for a single variable and a nonlinear equation for the scaling factor containing two variables using the surface fitting module.
Research results and their analysis
Characteristics of plant material
The average plant moisture content varied depending on the moisture content of individual plant components. Grain kernels exhibited the lowest moisture content (33.70%), followed by the core (47.35%), leaves (62.11%), and stems (73.38%). The moisture content of the maize plant stems varied along its height, ranging from 70 to 80% in the lower part, abruptly decreasing to 40% at a height of 1.10 m, corresponding to the location of the maize cobs, then gradually increasing again to approximately 70% at a height of 1.40 m, before gradually decreasing to 10–60% at the top of the stem, depending on plant height and maturity level, influenced by soil conditions. The moisture content of chopped maize plant material ranged between (55.57% and 59.25%) and (65.53% and 70.17%), respectively, for 57% and 68% moisture levels.
The geometric mean particle size of chopped maize plant material varied between 9.39 mm and 12.69 mm, corresponding to the operation of the cutting disc with 10 and 5 knives, respectively. Particle sizes were more significant when cutting material with a lower moisture of 57% compared to a higher moisture of 68%, measuring 11.79 mm and 10.29 mm, respectively.
The particle size distributions exhibited right-skewness, with graphic skewness coefficients ranging from 0.22 to 0.29. They were also leptokurtic, indicating a distribution with density concentrated around the mean value, as evidenced by positive values of the graphic kurtosis coefficients ranging from 0.97 to 0.99.
Characteristics of measurement signals
The obtained waveforms of capacitance changes indicated a signal drift over time. Analysis revealed that this drift occurred due to moisture deposition on the sensor walls from water in the plant material. Further investigation showed that this issue predominantly affected measurements from pairs of electrodes positioned close to each other.
Initially, the recorded data underwent processing using a third-order Butterworth high-pass filter, followed by determining the absolute value of the function36. Only data processed in this manner were utilised for subsequent analysis. This data processing procedure was applied to all recorded measurements, irrespective of the presence of drift. The individual steps of signal processing are illustrated in Figs. 11 and 12.
In the analysis of the results, Eq. 7 was employed to ascertain the scaling factor Wc (Fig. 13), utilising measurements of changes in sensor capacitance from individual pairs of electrodes.
where: WC—scaling factor, –, dk—the final value of the interval, s, dp—initial value of the interval, s, nw—number of nodes representing the discretisation of the measurement area, n—number of measurements, Ci—normalised capacitance value from individual pairs of electrodes.
Based on the generated data, scaling factors were computed, and a graph illustrating the changes in the WC value relative to the plant mass was plotted for different moisture levels and numbers of knives (Figs. 14 and 15). Table 1 summarises the WC scaling factor values for various combinations of input variables: material moisture content MC and number of knives z.
The computed values of the scaling factor Wc were utilised to approximate the correlation between the mass of plant material mC derived from the capacitance measurement data and the weighed mass of plant material m (Figs. 16 and 17).
The estimated mass values mC were utilised to compute the relative error eC for each set of decision variables, as per Eq. 8.
where eC—relative error, %, m—mass of the plant sample, as assumed, kg, mc—estimated value of the plant mass from the capacitance measurement data, kg.
The absolute error values for the assumed forage harvester operational systems are depicted in Figs. 18 and 19.
For each configuration, dependencies were found for changes in the scaling factor Wc concerning the moisture of the plant material MC and the number of knives z. For this purpose, the Statistica v. 13.3 program used surface-fitting to obtain Eq. 9.
where: WC—scaling factor, –, MC—plant material moisture content, %, z—number of knives in the chopped unit.
The graphical depiction of changes in the scaling factor based on the material moisture content and the number of knives in the chopping unit is illustrated in Fig. 20. Finally, Eq. 10 was derived for the instantaneous MFR of material qCt, considering the moisture of the plant material MC and the number of knives z.
where: qCt—MFR of plant material, kg·s[–1, WC—scaling factor, –, ti—time, s, Ci—normalised capacitance value from individual pairs of electrodes, n—number of sensor measurements.
The proposed Eq. 10 enables the correlation of changes in normalised capacitance values to an actual representation of variations in the MFR of plant material over time. Examples of such variations in the MFR of plant material qCt are depicted in Fig. 21. The graph illustrates fluctuations in the MFR of plant material over time, as captured using a 12-electrode sensor. The dataset pertains to a 15 kg sample, with a material moisture content of 57%, and employing 10 knives. The mean value of the MFR was 3.18 kg·s–1 with a standard deviation of 0.93 kg·s–1, and the theoretical value for these parameters was 3.75 kg·s–1. Thus, the error relative to the measurement was 15.2%. Through integral determination using the trapezoidal method, curve analysis provides insights into the total amount of plant material flowing at specific times.
During actual forage harvester tests, two issues were observed. In short-term evaluations, there was an issue with moisture condensing on the sensor walls. In contrast, the sensor became contaminated with minute plant material particles in long-term assessments, which distorted the measurement signal. Research conducted on a model measurement station indicated the method’s potential applicability. However, tests conducted under conditions resembling real-world scenarios using a forage harvester confirmed the design assumptions. Despite employing advanced signal processing techniques, the measurement error was approximately 30%. In contrast, other measurement methods achieved a more minor error of 10% 5. However, with its simplicity, non-intrusive measurement methodology, and low device cost, the ECT method remains a viable option for high-precision agriculture monitoring, particularly in crop management and processing applications37. It offers non-intrusive and real-time imaging, which can significantly benefit soil analysis and crop health monitoring38. With further enhancements in MFR measurement accuracy, the ECT method could solve the challenges in precision agriculture.
Our research uniquely contributes to developing agricultural technologies and improving the efficiency of capacitance measurement systems. The analysis, supported by an extensive literature review, indicated a crucial parameter in these systems—the excitation frequency. This is a decisive element for the measurement signal, especially in monitoring material with higher moisture content39. In the wood case, a parabolic relationship was identified between the sensor response and moisture content, where the increase in capacitance was more intense at higher moisture values40. Similarly, for chopped corn, the nonlinear dependence of the sensor output signals on the bulk density and moisture content of the material significantly affects the measurements, which must be considered when calibrating capacitive flow sensors13,15. Independent measurements of chopped corn moisture are essential for maintaining precision in practical conditions, and the increase in frequency leads to the linearisation of the relationship between capacitance and moisture, which allows for increased measurement accuracy. This unique finding, supported by the research of Zhang’s team41, has important practical implications, as it involves designing and constructing a new, modified measurement system.
The effect of moisture content and particle size on sensor capacitance is due to their direct impact on the dielectricity of the material, which is crucial for ECT measurements. Moisture increases the dielectricity of the material, which leads to an increase in the measured capacitance42. In turn, larger particles affect the uniformity of the electric field in the sensor, which can change local capacitance values. The interaction of these factors is essential for the accuracy of converting tonnage measurements to MFR, which is crucial in precision agriculture to monitor and optimise yields43.
The current system operates at a frequency of 625 kHz. To minimize the measurement error resulting from moisture accumulation on the sensors, operating at a minimum frequency of 10 MHz is recommended. The optimal solution would be to develop an ECT system with a programmable excitation frequency. This approach aligns with the findings emphasising frequency control’s critical role in improving ECT systems’ reliability and accuracy under different conditions.
Electrostatic sensors are used in many industries for efficient and cost-effective measurements. They are used, among others, in the analysis of flow processes in pipelines, where techniques such as cross-correlation allow the measurement of flow velocities of solids and gases44, and spatial filtering methods help study flow characteristics45. In addition, ECT is used to map concentration profiles using process tomography46, mass flow rate measurement47, moisture content estimation48, and average particle size determination49. These applications demonstrate the versatility of ECT and its potential for precise monitoring and control of industrial processes. Each application demonstrates how ECT and electrostatic sensors contribute to technological advances by offering robust and evidence-based methods crucial for industrial production efficiency and quality50.
This study has thoroughly investigated the characteristics of plant materials and measurement signals, which has expanded the knowledge of the capabilities of ECT in monitoring the yield of chopped maize. It demonstrates the significant influence of moisture and particle size on capacitance readings, which has important practical implications.
Advances in signal processing methodology have improved the accuracy of ECT systems in agriculture, paving the way for further research on developing this technology. Using ECT to measure the MFR of chopped corn is an excellent example of the effective integration of modern sensor technologies with traditional agricultural equipment, improving yield measurements’ precision and supporting long-term sustainable agriculture goals through better resource management and waste reduction. Furthermore, combining ECT with IoT technologies and cloud computing opens up new possibilities for precision farming, providing exciting development prospects for the future.
Conclusions
This study investigated the capabilities and effectiveness of ECT technology in monitoring the MFRs of chopped maize in the context of precision agriculture. On a stationary test bench with a self-propelled forage harvester, samples of Inagua maize were analysed with different weights (5, 10, 15 kg), which differed in moisture levels (57% or 68%) and particle size (9.39–12.69 mm), depending on the number of knives in the chopping unit. Using a 12-electrode capacitive sensor and a third-order Butterworth high-pass filter and the subsequent scaling factor calculation highlights the complex relationship between material properties and sensor performance, which is critical for an accurate performance estimate.
The findings of the study point to the potential benefits of adapting ECT technology to monitor maize yields. The hypothesis that ECT can precisely monitor the mass flow of chopped maize was confirmed, providing essential data regardless of changes in moisture and particle size, which is crucial for precision farming. Statistical analysis and new calibration methods have improved ECT measurements and practical usefulness. It also identified ways to minimise problems related to signal drift and sensor contamination by plant debris, which is crucial in field conditions. In addition, the innovative adjustment of the sensor’s excitation frequency enabled more precise measurements, which could be helpful for the further development of ECT technology in agriculture.
Moreover, the research has opened up exciting new possibilities for integrating ECT into precision farming systems, showcasing its potential for monitoring green crop yields. Looking ahead, the focus should be on optimising the design of ECT systems to accommodate higher operating frequencies, a development that could significantly enhance measurement accuracy and reliability. These results serve as a springboard for developing more reliable and flexible measurement systems that can effectively function in various agricultural conditions, inspiring hope for the future of ECT technology in agriculture.
Data availability
The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.
Abbreviations
- \({\overrightarrow{E}}_{i},{\overrightarrow{E}}_{j}\) :
-
Electric field distributions when electrodes i and j are the source electrodes, respectively
- C H :
-
Capacitance corresponding to high dielectric permittivity, F
- C i :
-
Normalised capacitance value from individual pairs of electrodes
- C ij :
-
Capacitance between electrodes i and j, F
- C L :
-
Signifies the capacitance corresponding to low dielectric permittivity, F
- C M :
-
Denotes the capacitance of the plant material, F
- C n :
-
Normalised capacitance
- d k :
-
The final value of the interval, s
- d p :
-
Initial value of the interval, s
- e C :
-
Relative error, %
- K n :
-
Normalised pixel permittivity
- m :
-
Mass of the plant sample, kg
- m c :
-
Estimated value of the plant mass from the capacitance measurement data, kg
- MC :
-
Plant material moisture content, %
- n :
-
Number of sensor measurements
- n w :
-
Number of nodes representing the discretisation of the measurement area
- q C t :
-
Mass flow rates of plant material, kg·s–1
- S n :
-
Normalised sensitivity matrices for each electrode pair
- t i :
-
Time, s
- W C :
-
Scaling factor
- x,y :
-
The Cartesian coordinates, m
- z :
-
Number of knives in the chopped unit
- ε(x,y):
-
Stands for the distribution of electric permittivity, F·m–1
- ϕ(x,y):
-
Signifies the potential distribution, V
- ϕ i :
-
Denotes the potential at electrode i, V
- ϕ j :
-
Refers to the potential at electrode j, V
References
Laveglia, S. et al. Adv. Sustainable Crop Management: Integrating Precision Agric. Proximal Sens. 3084–3120 (2024).
Xu, R. & Li, C. Development and Testing of a UAV-Based Multi-Sensor System for Plant Phenotyping and Precision Agriculture (2021).
Jones, J. W. et al. Toward a new generation of agricultural system data, models, and knowledge products: state of agricultural systems science. Agric. Syst. 155, 269–288 (2017).
Albahri, G., Alyamani, A. A., Badran, A., Hijazi, A. & Nasser, M. Enhancing Essential Grains Yield for Sustainable Food Security and Bio-Safe Agriculture through Latest Innovative Approaches 1–22 (2023).
Sishodia, R. P., Ray, R. L. & Singh, S. K. Applications of remote sensing in precision agriculture: A review. Remote Sens. 12, 1–31 (2020).
Baillie, C. P., Thomasson, J. A., Lobsey, C. R., McCarthy, C. L. & Antille, D. L. A review of the state of the Art in agricultural automation. Part I: sensing technologies for optimization of machine operation and farm inputs. ASABE 2018 Annu. Int. Meet. https://doi.org/10.13031/aim.201801589 (2018).
Lisowski, A. & Klonowski, J. Yield monitoring of grass based on plant material layer thickness measured between the Rear feeding rolls of the trailed forage harvester. Agric. Eng. 9, 83–91 (2005).
Vansichen, R. & De Baerdemaeker, J. A measurement technique for yield mapping of corn silage.pdf. J. Agric. Eng. Res. 55, 1–10 (1993).
Auernhammer, H., Demmel, M., Pirro, P. J. M. & Deere, J. Yield measurement on self propelled forage harvesters. ASAE-Paper No. 95-1757, Am. Soc. Agric. Eng. St. Joseph, MI, USA 1–10 (1995).
Ehlert, D. PA—Precision agriculture: advanced throughput measurement in forage harvesters. Biosyst. Eng. 83, 47–53 (2002).
Ehlert, D., Hammen, V. & Adamek, R. On-line sensor pendulum-meter for determination of plant mass. Precis. Agric. 4, 139–148 (2003).
Bagherpour, H. & Mohamadi, H. Challenges and prospects of precision agriculture in Iran. Int. J. Sci. Emerg. Technol. 17, 1–8 (2014).
Longchamps, L. et al. Yield sensing technologies for perennial and annual horticultural crops: a review. Precis. Agric. 23, 2407–2448 (2022).
Kumhála, F., Prošek, V. & Blahovec, J. Capacitive throughput sensor for sugar beets and potatoes. Biosyst. Eng. 102, 36–43 (2009).
Kumhala, F., Prosek, V. & Kroulik, M. Capacitive sensor for chopped maize throughput measurement. Comput. Electron. Agric. 70, 234–238 (2010).
Kumhála, F., Kavka, M. & Prošek, V. Capacitive throughput unit applied to stationary hop picking machine. Comput. Electron. Agric. 95, 92–97 (2013).
Mokhtar, Z. K. Gas/Solids Mass Flow Measurement by Electrical Capacitance Tomography and Electrostatic Sensors 1–72 (2018).
Yang, C. et al. Application of a high speed ECT system to online monitoring of pneumatic conveying process. Measurement 48, 29–42 (2014).
Mousazadeh, H., Tarabi, N. & Taghizadeh-Tameh, J. A fusion algorithm for mass flow rate measurement based on neural network and electrical capacitance tomography. Meas. J. Int. Meas. Confed. 231, 114573 (2024).
Rasel, R. K., Chowdhury, S. M., Marashdeh, Q. M. & Teixeira, F. L. Review of selected advances in electrical capacitance volume tomography for multiphase flow monitoring. Energies 15, 1–22 (2022).
Islam, M. Electrical Impedance Spectroscopy and Tomography: Applications on Plant Characterization (2019).
Gut, Z. Selected application of electrical capacitance tomography in monitoring of combustion process. Trans. Inst. Aviat. 245, 26–36 (2016).
Narayana, B. V. V. S., Ravi, K. S. & Ramesh, N. V. K. A review on advanced crop field monitoring system in agriculture field through top Notch sensors. J. Adv. Res. Dyn. Control Syst. 10, 1572–1578 (2018).
Lisowski, A. et al. Compaction of chopped material in a mini silo. Biomass Bioenergy 139, 1 (2020).
Lisowski, A. et al. Movement of chopped material in the discharge spout of forage harvester with a flywheel chopping unit: measurements using maize and numerical simulation. Biosyst. Eng. 111, 381–391 (2012).
Stoyan, D. & Zhang, Z. X. A stochastic model leading to various particle mass distributions including the RRSB distribution. Granul. Matter 25, 1–12 (2023).
Matkowski, P., Lisowski, A. & Świętochowski, A. Effect of compacted dose of pure straw and blends of straw with calcium carbonate or cassava starch on pelletising process and pellet quality. J. Clean. Prod. 277, 1 (2020).
Li, K., Chandrasekera, T. C., Li, Y. & Holland, D. J. A non-linear reweighted total variation image reconstruction algorithm for electrical capacitance tomography. IEEE Sens. J. 18, 5049–5057 (2018).
Huang, S. M., Stott, A. L., Green, R. G. & Beck, M. S. Electronic transducers for industrial measurement of low value capacitances. J. Phys. E 21, 242–250 (1988).
Guo, G., Yan, Y., Zhang, W., Hu, Y. & Fu, G. Measurement of moisture distribution in a biomass silo through electrical capacitance tomography. IEEE Trans. Instrum. Meas. 72, 1 (2023).
Wang, P., Lin, J. S. & Wang, M. An image reconstruction algorithm for electrical capacitance tomography based on simulated annealing particle swarm optimization. J. Appl. Res. Technol. 13, 197–204 (2015).
Yang, W. Design of electrical capacitance tomography sensors. Meas. Sci. Technol. 21, 1 (2010).
Brandisky, K., Romanowski, A. & Sankowski, D. Electrostatic field simulations in the analysis and design of electrical capacitance tomography sensors. Automatyka 14, 655–670 (2010).
Jiangbao, Y., Lei, Z., Feng, Z., Tan, X. & Changsheng, Z. An improved normalized model of electrical capacitance tomography. MATEC Web Conf. 176, 1–5 (2018).
Lisowski, A. et al. Energy of feeding and chopping of biomass processing in the working units of forage harvester and energy balance of methane production from selected energy plants species. Biomass Bioenerg. 128, 1 (2019).
Vanwanseele, B., De Beéck, O., Schütte, T., Davis, J. & K. & Accelerometer based data can provide a better estimate of cumulative load during running compared to GPS based parameters. Front. Sport Act. Living 2, 1–7 (2020).
Xu, Z. et al. DCGAN-based image enhancement in electrical capacitance tomography. In IST 2023 - IEEE Int. Conf. Imaging Syst. Tech. Proc. 10355653. https://doi.org/10.1109/IST59124.2023.10355653 (2023).
Khosrokhani, M., Khairunniza-Bejo, S. & Pradhan, B. Geospatial technologies for detection and monitoring of ganoderma basal stem rot infection in oil palm plantations: a review on sensors and techniques. Geocarto Int. 33, 260–276 (2018).
Hosseini, M., Kaasinen, A., Link, G., Lahivaara, T. & Vauhkonen, M. Electrical capacitance tomography to measure moisture distribution of polymer foam in a microwave drying process. IEEE Sens. J. 21, 18101–18114 (2021).
Moron, C., Garcia-Fuentevilla, L., Garcia, A. & Moron, A. Measurement of moisture in wood for application in the restoration of old buildings. Sensors (Switzerland) 16, 1–10 (2016).
Zhang, W., Wang, C., Yang, W. & Wang, C. H. Application of electrical capacitance tomography in particulate process measurement—A review. Adv. Powder Technol. 25, 174–188 (2014).
Zabolotnyi, O. & Koshevoi, M. An effective method of bulk materials moisture measurement using capacitive sensors. J. Stored Prod. Res. 89, 101733 (2020).
Culaba, A. B. et al. Design of biorefineries towards carbon neutrality: A critical review. Bioresour. Technol. 369, 128256 (2023).
Wang, C., Zhang, J., Gao, W., Ding, H. & Wu, W. Cross-correlation focus method with an electrostatic sensor array for local particle velocity measurement in dilute gas-solid two-phase flow. Meas. Sci. Technol. 26, 115301 (2015).
Wen, Z., Ma, X. & Zuo, H. Characteristics analysis and experiment verification of electrostatic sensor for aero-engine exhaust gas monitoring. Meas. J. Int. Meas. Confed. 47, 633–644 (2014).
Tang, X., Chen, Z., Li, Y. & Yang, Y. Compressive sensing-based electrostatic sensor array signal processing and exhausted abnormal debris detecting. Mech. Syst. Signal. Process. 105, 404–426 (2018).
Qian, X., Yan, Y., Huang, X. & Hu, Y. Measurement of the mass flow and velocity distributions of pulverized fuel in primary air pipes using electrostatic sensing techniques. IEEE Trans. Instrum. Meas. 66, 944–952 (2017).
Zhang, W., Cheng, X., Hu, Y. & Yan, Y. Measurement of moisture content in a fluidized bed dryer using an electrostatic sensor array. Powder Technol. 325, 49–57 (2018).
Tajdari, T., Rahmat, M. F. & Wahab, N. A. ad New technique to measure particle size using electrostatic sensor. J. Electrostat. 72, 120–128 (2014).
Mazur, F., Han, Z., Tjandra, A. D. & Chandrawati, R. Digitalization of colorimetric sensor technologies for food safety. Adv. Mater. 2404274, 1 (2024).
Acknowledgements
This research was funded by the National Centre for Research and Development under the PBS program, a government initiative aimed at promoting scientific research and development in Poland, contract No. PBS2/A8/18/2013. The publication was (co)financed by the Science Development Fund of the Warsaw University of Life Sciences - SGGW.
Author information
Authors and Affiliations
Contributions
Author Contributions: Conceptualization, Z.G., A.L. and J.K.; methods, Z.G., J.K., A.L. and A.Ś.; software, Z.G.; formal analysis, Z.G.; investigation, Z.G., A.L., J.K. and A.Ś.; resources, Z.G. and A.L; data curation, Z.G. and A.L.; writing—original draft preparation, Z.G. and A.L.; writing—review and editing, A.L., J.K. and A.Ś.; visualization, Z.G. and A.L.; project administration, Z.G. and A.L.; supervision, Z.G. All authors have read and agreed to the published version of the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
The original online version of this Article was revised: The Acknowledgements section in the original version of this Article was incomplete. It now reads: “This research was funded by the National Centre for Research and Development under the PBS program, a government initiative aimed at promoting scientific research and development in Poland, contract No. PBS2/A8/18/2013. The publication was (co)financed by the Science Development Fund of the Warsaw University of Life Sciences - SGGW."
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Gut, Z., Lisowski, A., Klonowski, J. et al. Assessing the capability of electrical capacitance tomography for monitoring chopped maize mass flow rates in field forage harvesters. Sci Rep 15, 13125 (2025). https://doi.org/10.1038/s41598-025-97427-z
Received:
Accepted:
Published:
Version of record:
DOI: https://doi.org/10.1038/s41598-025-97427-z