134 changes: 134 additions & 0 deletions bundles/binding/org.openhab.binding.zwave/database/aeon/zw120.xml
Original file line number Diff line number Diff line change
@@ -0,0 +1,134 @@
<?xml version="1.0" encoding="utf-8"?>
<!--
Aeotec ZW120 Door/Window Sensor Gen5, base on Engineering Spec 08/01/2016
from https://github.com/OpenZWave/open-zwave/blob/master/config/aeotec/zw120.xml
-->
<Product>
<Model>ZW120-A</Model>
<Label lang="en">Door/Window sensor Gen5</Label>
<CommandClasses>
<Class><id>0x20</id></Class>
<Class><id>0x70</id></Class>
<Class><id>0x80</id></Class>
<Class><id>0x00</id></Class>
<Class><id>0x30</id></Class>
<Class><id>0x71</id></Class>
<Class><id>0x86</id></Class>
<Class><id>0x72</id></Class>
<Class><id>0x84</id></Class>
<Class><id>0x85</id></Class>
</CommandClasses>
<Configuration>
<Parameter>
<Index>1</Index>
<Type>list</Type>
<Default>0</Default>
<Size>1</Size>
<Label lang="en">Which value of the Sensor Binary Report or Basic Set will be sent when the Magnet is triggered On/Off.</Label>
<Item>
<Value>0</Value>
<Label lang="en">On=Sensor Binary Report/Basic Set 0xFF; Off=Sensor Binary Report/Basic Set 0x00</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">On=Sensor Binary Report/Basic Set 0x00; Off=Sensor Binary Report/Basic Set 0xFF</Label>
</Item>
</Parameter>
<Parameter>
<Index>2</Index>
<Type>list</Type>
<Default>1</Default>
<Minimum>0</Minimum>
<Maximum>1</Maximum>
<Size>1</Size>
<Label lang="en">Enable wake up 10 minutes when re-power on the sensor</Label>
<Help>Default setting: Disable</Help>
<Item>
<Value>0</Value>
<Label lang="en">Disable</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Enable</Label>
</Item>
</Parameter>
<Parameter>
<Index>3</Index>
<Type>list</Type>
<Default>0</Default>
<Minimum>0</Minimum>
<Maximum>1</Maximum>
<Size>1</Size>
<Label lang="en">Basic Set Report</Label>
<Help>Which value of the Basic Set will be sent when the door is Opened/Closed</Help>
<Item>
<Value>0</Value>
<Label lang="en">Open: 0xFF, Close: 0x00</Label>
</Item>
<Item>
<Value>1</Value>
<Label lang="en">Open: 0x00, Close: 0xFF</Label>
</Item>
</Parameter>
<Parameter>
<Index>39</Index>
<Type>byte</Type>
<Default>10</Default>
<Minimum>10</Minimum>
<Maximum>50</Maximum>
<Size>1</Size>
<Label lang="en">Set the low battery value.</Label>
<Help lang="en">10% to 50%</Help>
</Parameter>
<Parameter>
<Index>111</Index>
<Type>byte</Type>
<Minimum>0</Minimum>
<Maximum>2147483647</Maximum>
<Default>86640</Default>
<Size>4</Size>
<Label lang="en">Set the interval time of low battery checking.</Label>
<Help lang="en">Minimum interval is 4 minutes, Range is 0 to 2147483647</Help>
</Parameter>
<Parameter>
<Index>121</Index>
<Type>int</Type>
<Default>1</Default>
<Size>4</Size>
<Minimum>0</Minimum>
<Maximum>65535</Maximum>
<!--<value>256</value>-->
<Label lang="en">Report type</Label>
<Help>To configure which sensor report will be sent when the Sensor is triggered Opened/Closed. Bitsets: 0->Battery report, 4->Sensor Binary, 8->Basic Set, Default setting: 0x00000100 (Basic Set).Ideal Setting for OZW is 17 (Sensor Binary and Battery Report).</Help>
</Parameter>
<Parameter>
<Index>255</Index>
<Type>list</Type>
<Default>0</Default>
<Size>4</Size>
<!--<Value>1</Value>-->
<!--<Write_only>true</Write_only>-->
<Label lang="en">Reset To Factory Defaults.</Label>
<Item>
<Label lang="en">Reset to factory default setting</Label>
<Value>0</Value>
</Item>
<Item>
<Label lang="en">Normal</Label>
<Value>1</Value>
</Item>
<Item>
<Label lang="en">Reset to factory default setting and removed from the z-wave network</Label>
<Value>1431655765</Value>
</Item>
</Parameter>
</Configuration>
<Associations>
<Group>
<Index>1</Index>
<Maximum>5</Maximum>
<Label lang="en">Group 1</Label>
<SetToController>true</SetToController>
</Group>
</Associations>
</Product>
18 changes: 18 additions & 0 deletions bundles/binding/org.openhab.binding.zwave/database/products.xml
Original file line number Diff line number Diff line change
Expand Up @@ -653,6 +653,10 @@
<Type>4952</Type>
<Id>3031</Id>
</Reference>
<Reference>
<Type>5052</Type>
<Id>3031</Id>
</Reference>
<Model>45605</Model>
<Label lang="en">Smart Outlet</Label>
<ConfigFile>ge/receptacle.xml</ConfigFile>
Expand Down Expand Up @@ -998,6 +1002,16 @@
<Label lang="de">Tür-Fenster-Sensor</Label>
<ConfigFile>aeon/doorsensor.xml</ConfigFile>
</Product>
<Product>
<Reference>
<Type>102</Type>
<Id>78</Id>
</Reference>
<Model>ZW120-a</Model>
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Please change the name to ZW120

<Label lang="en">Door/Window sensor Gen5</Label>
<Label lang="de">Tür-Fenster-Sensor Gen5</Label>
<ConfigFile>aeon/zw120.xml</ConfigFile>
</Product>
<Product>
<Reference>
<Type>0002</Type>
Expand Down Expand Up @@ -2804,6 +2818,10 @@
<Type>0101</Type>
<Id>8377</Id>
</Reference>
<Reference>
<Type>0100</Type>
<Id>8377</Id>
</Reference>
<Model>ZXT-120</Model>
<Label lang="en">Remotec ZXT-120 AC IR Remote</Label>
<ConfigFile>remotec/zxt120.xml</ConfigFile>
Expand Down