This library enables communication with systems based on the eBUS protocol. eBUS is primarily used in the heating industry.
- The eBUS works on a two-wire bus with a speed of 2400 baud.
- Realisation with Standard UART with 8 bits + start bit + stop bit.
- A maximum of 25 master and 228 slave participants are possible.
- The eBUS protocol is byte-oriented with byte-oriented arbitration.
- Data protection through 8-bit CRC.
On the bus, a message is sent or received as a sequence of characters.
- The purpose of the Sequence (low-level) class is to replace or insert special characters and calculate the CRC byte.
- The Telegram (high-level) class can analyze, generate and evaluate a sequence according to the eBUS specification.
- The Handler has routines for sending and receiving all types of telegrams and the option of collecting statistical data about the eBUS system. To perform this task, the Handler requires a serial bus device.
- Datatypes offers functions for decoding/encoding of in accordance with the eBUS data types.
- Bus, BusIsr, Queue and ServiceRunner are selector header files that include platform-specific implementations.
ebusread interprets all incoming values as eBUS data. The data is validated and then printed to standard output. Reading from files, devices, pipes and TCP sockets is supported.
playground can be used by developers for testing and experimenting with the eBUS classes.
Compilation requires CMake and a C++ compiler (tested on GCC) with C++14 support.
EbusStack offers the possibility to act as a fully-fledged eBUS participant. It has been implemented as a PIMPL idiom and runs in its own thread. EbusStack also requires ppoll and pthread support.